43
Appendix
Command form
Default Parameters Description
Name Short
FIRMRNR FIR OFF ON/OFF The other station sends a notice (packet) to you if it is not
ready to receive data. When ON, receiving such a notice
causes the TNC to suspend transmission until it receives a
“ready” notice.
FLOW F ON ON/OFF
When ON, starting key entry causes the computer to stop
displaying received packets.
FRACK FR 3 0 - 250 Specifies the interval from one transmission until retry
of transmission. The unit of the parameter is 1 second.
GBAUD GB 4800 4800/9600 Selects 4800 or 9600 bps as the transfer rate between
the TNC and the GPS receiver.
GPSSEND GPSS - 0 - 159 Specifies the content of the data to be output to the GPS
characters receiver; this data is used to pro gram the default settings on
the receiver. The output data is not stored in memory.
GPSTEXT GPST $PNTS 0 - 6 Specifies the type of a message to be determined by
characters LTEXT.
HBAUD HB 1200 1200/9600 Selects 1200 or 9600 bps as the transfer rate between
packet stations.
LOCATION
LOC EVERY 0 EVERY/ If set to EVERY, sends GPS data at intervals of the speci-
AFTER n fied period (n). If set to AFTER, sends GPS data only once
( n = 0 - 250 ) after the specified period (n). The unit of n is 10 seconds.
LPATH LPA GPS Call1 ( VIA Specifies calls signs to send GPS data. Call 1 is the call sign
call2, call3, ... of the destination. Call2 to call9 are call signs of stations to
call9 ) be digipeated through.
LTEXT LT - 0 - 159 Specifies the content of a message to be included in GPS
characters data.
LTMON LTM 0 0 - 250 Specifies the interval for displaying a message determined
by LTEXT on the screen; a message appears like a received
beacon packet. The unit of the parameter is 1 second.
MCOM MCOM OFF ON/OFF When ON, causes the TNC to also monitor control packets.
When OFF, causes it to monitor only information packets.
MCON MC OFF ON/OFF When ON, causes the TNC to monitor other stations
while in connection with the target station.
MONITOR M ON ON/OFF When ON, causes the TNC to monitor packets.
MRPT MR ON ON/OFF When ON, causes the TNC to display the entire digipeat
list for monitored packets.
MYCALL MY NOCALL 6 characters Specifies your call sign.
+SSID
PACLEN P 128 0 - 255 Specifies the maximum length of the data portion of a
packet.
PACTIME PACT AFTER 10 EVERY/ If set to EVERY, sends a packet at intervals of the specified
AFTER n period (n). If set to AFTER, sends a packet only once after
( n = 0 - 250 ) the specified period of (n). The unit of n is 100 milliseconds.
PERSIST PE 128 128 Specifies a parameter to calculate probability for the
PERSIST/SLOTTIME method.
PPERSIST PP ON ON Causes the TNC to use the PERSIST/SLOTTIME method
when ON, or the DWAIT method when OFF.